adds apcupsd, thanks Matthias Eller , fixes #2157
git-svn-id: svn://svn.openwrt.org/openwrt/packages@11971 3c298f89-4303-0410-b956-a3cf2f4a3e73
This commit is contained in:
parent
b4a652dfa5
commit
204f73c930
67
net/apcupsd/Makefile
Normal file
67
net/apcupsd/Makefile
Normal file
@ -0,0 +1,67 @@
|
||||
#
|
||||
# Copyright (C) 2006 OpenWrt.org
|
||||
#
|
||||
# This is free software, licensed under the GNU General Public License v2.
|
||||
# See /LICENSE for more information.
|
||||
#
|
||||
# $Id: Makefile 6500 2007-03-04 04:19:46Z pavlov $
|
||||
|
||||
include $(TOPDIR)/rules.mk
|
||||
|
||||
PKG_NAME:=apcupsd
|
||||
PKG_VERSION:=3.14.2
|
||||
PKG_RELEASE:=1
|
||||
|
||||
PKG_SOURCE:=$(PKG_NAME)-$(PKG_VERSION).tar.gz
|
||||
PKG_SOURCE_URL:=@SF/apcupsd
|
||||
PKG_MD5SUM:=fd8785e7607d20cefa68dc20e44eebc4
|
||||
PKG_CAT:=zcat
|
||||
|
||||
PKG_BUILD_DIR:=$(BUILD_DIR)/$(PKG_NAME)-$(PKG_VERSION)
|
||||
#PKG_INSTALL_DIR:=$(PKG_BUILD_DIR)/ipkg-install
|
||||
PKG_INSTALL_DIR:=$(BUILD_DIR)/apcupsd-ipkg-install
|
||||
|
||||
include $(INCLUDE_DIR)/package.mk
|
||||
|
||||
define Package/apcupsd
|
||||
SECTION:=utils
|
||||
CATEGORY:=Utilities
|
||||
DEPENDS:=+libpthread
|
||||
TITLE:=UPS control software
|
||||
URL:=http://www.apcupsd.org/
|
||||
endef
|
||||
|
||||
define Build/Configure
|
||||
$(call Build/Configure/Default, \
|
||||
--with-distname=unknown \
|
||||
--sysconfdir=/etc/apcupsd \
|
||||
)
|
||||
endef
|
||||
|
||||
define Build/Compile
|
||||
$(MAKE) -C $(PKG_BUILD_DIR) \
|
||||
DESTDIR="$(PKG_INSTALL_DIR)" \
|
||||
LD="$(TARGET_CC)" \
|
||||
all install
|
||||
endef
|
||||
|
||||
define Package/apcupsd/install
|
||||
$(INSTALL_DIR) $(1)/usr/sbin
|
||||
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/apcupsd $(1)/usr/sbin/
|
||||
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/smtp $(1)/usr/sbin/
|
||||
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/apctest $(1)/usr/sbin/
|
||||
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/apcaccess $(1)/usr/sbin/
|
||||
$(INSTALL_DIR) $(1)/etc/apcupsd
|
||||
$(INSTALL_CONF) ./files/apcupsd.conf $(1)/etc/apcupsd/
|
||||
$(INSTALL_CONF) ./files/apcupsd_mail.conf $(1)/etc/apcupsd/
|
||||
$(INSTALL_BIN) ./files/changeme $(1)/etc/apcupsd/
|
||||
$(INSTALL_BIN) ./files/commfailure $(1)/etc/apcupsd/
|
||||
$(INSTALL_BIN) ./files/commok $(1)/etc/apcupsd/
|
||||
$(INSTALL_BIN) ./files/offbattery $(1)/etc/apcupsd/
|
||||
$(INSTALL_BIN) ./files/onbattery $(1)/etc/apcupsd/
|
||||
$(INSTALL_BIN) ./files/apccontrol $(1)/etc/apcupsd/
|
||||
$(INSTALL_DIR) $(1)/etc/init.d
|
||||
$(INSTALL_BIN) ./files/apcupsd.init $(1)/etc/init.d/apcupsd
|
||||
endef
|
||||
|
||||
$(eval $(call BuildPackage,apcupsd))
|
146
net/apcupsd/files/apccontrol
Normal file
146
net/apcupsd/files/apccontrol
Normal file
@ -0,0 +1,146 @@
|
||||
#!/bin/sh
|
||||
#
|
||||
# Copyright (C) 1999-2002 Riccardo Facchetti <riccardo@master.oasi.gpa.it>
|
||||
#
|
||||
# for apcupsd release 3.14.1 (04 May 2007) - unknown
|
||||
#
|
||||
# platforms/apccontrol. Generated from apccontrol.in by configure.
|
||||
#
|
||||
# Note, this is a generic file that can be used by most
|
||||
# systems. If a particular system needs to have something
|
||||
# special, start with this file, and put a copy in the
|
||||
# platform subdirectory.
|
||||
#
|
||||
|
||||
#
|
||||
# These variables are needed for set up the autoconf other variables.
|
||||
#
|
||||
prefix=/usr
|
||||
exec_prefix=/usr
|
||||
|
||||
APCPID=/var/run/apcupsd.pid
|
||||
APCUPSD=/usr/sbin/apcupsd
|
||||
SHUTDOWN=/sbin/shutdown
|
||||
SCRIPTSHELL=/bin/sh
|
||||
SCRIPTDIR=/etc/apcupsd
|
||||
WALL=true
|
||||
|
||||
#
|
||||
# Concatenate all output from this script to the events file
|
||||
# Note, the following kills the script in a power fail situation
|
||||
# where the disks are mounted read-only.
|
||||
# exec >>/var/log/apcupsd.events 2>&1
|
||||
|
||||
#
|
||||
# This piece is to substitute the default behaviour with your own script,
|
||||
# perl, or C program.
|
||||
# You can customize every single command creating an executable file (may be a
|
||||
# script or a compiled program) and calling it the same as the $1 parameter
|
||||
# passed by apcupsd to this script.
|
||||
#
|
||||
# After executing your script, apccontrol continues with the default action.
|
||||
# If you do not want apccontrol to continue, exit your script with exit
|
||||
# code 99. E.g. "exit 99".
|
||||
#
|
||||
# WARNING: the apccontrol file will be overwritten every time you update your
|
||||
# apcupsd, doing `make install'. Your own customized scripts will _not_ be
|
||||
# overwritten. If you wish to make changes to this file (discouraged), you
|
||||
# should change apccontrol.sh.in and then rerun the configure process.
|
||||
#
|
||||
if [ -f ${SCRIPTDIR}/${1} -a -x ${SCRIPTDIR}/${1} ]
|
||||
then
|
||||
${SCRIPTDIR}/${1} ${2} ${3} ${4}
|
||||
# exit code 99 means he does not want us to do default action
|
||||
if [ $? = 99 ] ; then
|
||||
exit 0
|
||||
fi
|
||||
fi
|
||||
|
||||
case "$1" in
|
||||
killpower)
|
||||
echo "Apccontrol doing: ${APCUPSD} --killpower on UPS ${2}"
|
||||
sleep 10
|
||||
${APCUPSD} --killpower
|
||||
echo "Apccontrol has done: ${APCUPSD} --killpower on UPS ${2}" | ${WALL}
|
||||
;;
|
||||
commfailure)
|
||||
echo "Warning communications lost with UPS ${2}" | ${WALL}
|
||||
;;
|
||||
commok)
|
||||
echo "Communications restored with UPS ${2}" | ${WALL}
|
||||
;;
|
||||
#
|
||||
# powerout, onbattery, offbattery, mainsback events occur
|
||||
# in that order.
|
||||
#
|
||||
powerout)
|
||||
echo "Warning power loss detected on UPS ${2}" | ${WALL}
|
||||
;;
|
||||
onbattery)
|
||||
echo "Power failure on UPS ${2}. Running on batteries." | ${WALL}
|
||||
;;
|
||||
offbattery)
|
||||
;;
|
||||
mainsback)
|
||||
echo "Power has returned on UPS ${2}..." | ${WALL}
|
||||
if [ -f /etc/powerfail ] ; then
|
||||
printf "Continuing with shutdown." | ${WALL}
|
||||
fi
|
||||
;;
|
||||
failing)
|
||||
echo "Battery power exhaused on UPS ${2}. Doing shutdown." | ${WALL}
|
||||
;;
|
||||
timeout)
|
||||
echo "Battery time limit exceeded on UPS ${2}. Doing shutdown." | ${WALL}
|
||||
;;
|
||||
loadlimit)
|
||||
echo "Remaining battery charge below limit on UPS ${2}. Doing shutdown." | ${WALL}
|
||||
;;
|
||||
runlimit)
|
||||
echo "Remaining battery runtime below limit on UPS ${2}. Doing shutdown." | ${WALL}
|
||||
;;
|
||||
doreboot)
|
||||
echo "UPS ${2} initiating Reboot Sequence" | ${WALL}
|
||||
${SHUTDOWN} -r now "apcupsd UPS ${2} initiated reboot"
|
||||
;;
|
||||
doshutdown)
|
||||
echo "UPS ${2} initiated Shutdown Sequence" | ${WALL}
|
||||
${SHUTDOWN} -h now "apcupsd UPS ${2} initiated shutdown"
|
||||
;;
|
||||
annoyme)
|
||||
echo "Power problems with UPS ${2}. Please logoff." | ${WALL}
|
||||
;;
|
||||
emergency)
|
||||
echo "Emergency Shutdown. Possible battery failure on UPS ${2}." | ${WALL}
|
||||
;;
|
||||
changeme)
|
||||
echo "Emergency! Batteries have failed on UPS ${2}. Change them NOW" | ${WALL}
|
||||
;;
|
||||
remotedown)
|
||||
echo "Remote Shutdown. Beginning Shutdown Sequence." | ${WALL}
|
||||
;;
|
||||
restartme)
|
||||
echo -n "Restarting APCUPSD Power Management: "
|
||||
THEPID=`cat ${APCPID}`
|
||||
kill ${THEPID}
|
||||
rm -f ${APCPID}
|
||||
rm -f /etc/powerfail
|
||||
rm -f /etc/nologin
|
||||
sleep 5
|
||||
`${APCUPSD}`
|
||||
echo "apcupsd"
|
||||
;;
|
||||
startselftest)
|
||||
;;
|
||||
endselftest)
|
||||
;;
|
||||
battdetach)
|
||||
;;
|
||||
battattach)
|
||||
;;
|
||||
*) echo "Usage: ${0##*/} command"
|
||||
echo " warning: this script is intended to be launched by"
|
||||
echo " apcupsd and should never be launched by users."
|
||||
exit 1
|
||||
;;
|
||||
esac
|
322
net/apcupsd/files/apcupsd.conf
Normal file
322
net/apcupsd/files/apcupsd.conf
Normal file
@ -0,0 +1,322 @@
|
||||
## apcupsd.conf v1.1 ##
|
||||
#
|
||||
# for apcupsd release 3.14.1 (04 May 2007) - unknown
|
||||
#
|
||||
# "apcupsd" POSIX config file
|
||||
|
||||
#
|
||||
# ========= General configuration parameters ============
|
||||
#
|
||||
|
||||
# UPSNAME xxx
|
||||
# Use this to give your UPS a name in log files and such. This
|
||||
# is particulary useful if you have multiple UPSes. This does not
|
||||
# set the EEPROM. It should be 8 characters or less.
|
||||
UPSNAME ups1
|
||||
|
||||
# UPSCABLE <cable>
|
||||
# Defines the type of cable connecting the UPS to your computer.
|
||||
#
|
||||
# Possible generic choices for <cable> are:
|
||||
# simple, smart, ether, usb
|
||||
#
|
||||
# Or a specific cable model number may be used:
|
||||
# 940-0119A, 940-0127A, 940-0128A, 940-0020B,
|
||||
# 940-0020C, 940-0023A, 940-0024B, 940-0024C,
|
||||
# 940-1524C, 940-0024G, 940-0095A, 940-0095B,
|
||||
# 940-0095C, M-04-02-2000
|
||||
#
|
||||
UPSCABLE smart
|
||||
|
||||
# To get apcupsd to work, in addition to defining the cable
|
||||
# above, you must also define a UPSTYPE, which corresponds to
|
||||
# the type of UPS you have (see the Description for more details).
|
||||
# You must also specify a DEVICE, sometimes referred to as a port.
|
||||
# For USB UPSes, please leave the DEVICE directive blank. For
|
||||
# other UPS types, you must specify an appropriate port or address.
|
||||
#
|
||||
# UPSTYPE DEVICE Description
|
||||
# apcsmart /dev/tty** Newer serial character device,
|
||||
# appropriate for SmartUPS models using
|
||||
# a serial cable (not USB).
|
||||
#
|
||||
# usb <BLANK> Most new UPSes are USB. A blank DEVICE
|
||||
# setting enables autodetection, which is
|
||||
# the best choice for most installations.
|
||||
#
|
||||
# net hostname:port Network link to a master apcupsd
|
||||
# through apcupsd's Network Information
|
||||
# Server. This is used if you don't have
|
||||
# a UPS directly connected to your computer.
|
||||
#
|
||||
# snmp hostname:port:vendor:community
|
||||
# SNMP Network link to an SNMP-enabled
|
||||
# UPS device. Vendor is the MIB used by
|
||||
# the UPS device: can be "APC", "APC_NOTRAP"
|
||||
# or "RFC" where APC is the powernet MIB,
|
||||
# "APC_NOTRAP" is powernet with SNMP trap
|
||||
# catching disabled, and RFC is the IETF's
|
||||
# rfc1628 UPS-MIB. You usually want "APC".
|
||||
# Port is usually 161. Community is usually
|
||||
# "private".
|
||||
#
|
||||
# dumb /dev/tty** Old serial character device for use
|
||||
# with simple-signaling UPSes.
|
||||
#
|
||||
# pcnet ipaddr:username:passphrase
|
||||
# PowerChute Network Shutdown protocol
|
||||
# which can be used as an alternative to SNMP
|
||||
# with AP9617 family of smart slot cards.
|
||||
# ipaddr is the IP address of the UPS mgmt
|
||||
# card. username and passphrase are the
|
||||
# credentials for which the card has been
|
||||
# configured.
|
||||
#
|
||||
UPSTYPE apcsmart
|
||||
DEVICE /dev/ttyS0
|
||||
|
||||
|
||||
# LOCKFILE <path to lockfile>
|
||||
# Path for device lock file. Not used on Win32.
|
||||
LOCKFILE /var/lock
|
||||
|
||||
# SCRIPTDIR <path to script directory>
|
||||
# Directory in which apccontrol and event scripts are located.
|
||||
SCRIPTDIR /etc/apcupsd
|
||||
|
||||
# PWRFAILDIR <path to powerfail directory>
|
||||
# Directory in which to write the powerfail flag file. This file
|
||||
# is created when apcupsd initiates a system shutdown and is
|
||||
# checked in the OS halt scripts to determine if a killpower
|
||||
# (turning off UPS output power) is required.
|
||||
PWRFAILDIR /etc
|
||||
|
||||
# NOLOGINDIR <path to nologin directory>
|
||||
# Directory in which to write the nologin file. The existence
|
||||
# of this flag file tells the OS to disallow new logins.
|
||||
NOLOGINDIR /etc
|
||||
|
||||
|
||||
#
|
||||
# ======== Configuration parameters used during power failures ==========
|
||||
#
|
||||
|
||||
# The ONBATTERYDELAY is the time in seconds from when a power failure
|
||||
# is detected until we react to it with an onbattery event.
|
||||
#
|
||||
# This means that, apccontrol will be called with the powerout argument
|
||||
# immediately when a power failure is detected. However, the
|
||||
# onbattery argument is passed to apccontrol only after the
|
||||
# ONBATTERYDELAY time. If you don't want to be annoyed by short
|
||||
# powerfailures, make sure that apccontrol powerout does nothing
|
||||
# i.e. comment out the wall.
|
||||
#ONBATTERYDELAY 6
|
||||
|
||||
#
|
||||
# Note: BATTERYLEVEL, MINUTES, and TIMEOUT work in conjunction, so
|
||||
# the first that occurs will cause the initation of a shutdown.
|
||||
#
|
||||
|
||||
# If during a power failure, the remaining battery percentage
|
||||
# (as reported by the UPS) is below or equal to BATTERYLEVEL,
|
||||
# apcupsd will initiate a system shutdown.
|
||||
BATTERYLEVEL 5
|
||||
|
||||
# If during a power failure, the remaining runtime in minutes
|
||||
# (as calculated internally by the UPS) is below or equal to MINUTES,
|
||||
# apcupsd, will initiate a system shutdown.
|
||||
MINUTES 3
|
||||
|
||||
# If during a power failure, the UPS has run on batteries for TIMEOUT
|
||||
# many seconds or longer, apcupsd will initiate a system shutdown.
|
||||
# A value of 0 disables this timer.
|
||||
#
|
||||
# Note, if you have a Smart UPS, you will most likely want to disable
|
||||
# this timer by setting it to zero. That way, you UPS will continue
|
||||
# on batteries until either the % charge remaing drops to or below BATTERYLEVEL,
|
||||
# or the remaining battery runtime drops to or below MINUTES. Of course,
|
||||
# if you are testing, setting this to 60 causes a quick system shutdown
|
||||
# if you pull the power plug.
|
||||
# If you have an older dumb UPS, you will want to set this to less than
|
||||
# the time you know you can run on batteries.
|
||||
TIMEOUT 0
|
||||
|
||||
# Time in seconds between annoying users to signoff prior to
|
||||
# system shutdown. 0 disables.
|
||||
ANNOY 300
|
||||
|
||||
# Initial delay after power failure before warning users to get
|
||||
# off the system.
|
||||
ANNOYDELAY 60
|
||||
|
||||
# The condition which determines when users are prevented from
|
||||
# logging in during a power failure.
|
||||
# NOLOGON <string> [ disable | timeout | percent | minutes | always ]
|
||||
NOLOGON disable
|
||||
|
||||
# If KILLDELAY is non-zero, apcupsd will continue running after a
|
||||
# shutdown has been requested, and after the specified time in
|
||||
# seconds attempt to kill the power. This is for use on systems
|
||||
# where apcupsd cannot regain control after a shutdown.
|
||||
# KILLDELAY <seconds> 0 disables
|
||||
KILLDELAY 0
|
||||
|
||||
#
|
||||
# ==== Configuration statements for Network Information Server ====
|
||||
#
|
||||
|
||||
# NETSERVER [ on | off ] on enables, off disables the network
|
||||
# information server. If netstatus is on, a network information
|
||||
# server process will be started for serving the STATUS and
|
||||
# EVENT data over the network (used by CGI programs).
|
||||
NETSERVER on
|
||||
|
||||
# NISIP <dotted notation ip address>
|
||||
# IP address on which NIS server will listen for incoming connections.
|
||||
# This is useful if your server is multi-homed (has more than one
|
||||
# network interface and IP address). Default value is 0.0.0.0 which
|
||||
# means any incoming request will be serviced. Alternatively, you can
|
||||
# configure this setting to any specific IP address of your server and
|
||||
# NIS will listen for connections only on that interface. Use the
|
||||
# loopback address (127.0.0.1) to accept connections only from the
|
||||
# local machine.
|
||||
NISIP 0.0.0.0
|
||||
|
||||
# NISPORT <port> default is 3551 as registered with the IANA
|
||||
# port to use for sending STATUS and EVENTS data over the network.
|
||||
# It is not used unless NETSERVER is on. If you change this port,
|
||||
# you will need to change the corresponding value in the cgi directory
|
||||
# and rebuild the cgi programs.
|
||||
NISPORT 3551
|
||||
|
||||
# If you want the last few EVENTS to be available over the network
|
||||
# by the network information server, you must define an EVENTSFILE.
|
||||
EVENTSFILE /var/log/apcupsd.events
|
||||
|
||||
# EVENTSFILEMAX <kilobytes>
|
||||
# By default, the size of the EVENTSFILE will be not be allowed to exceed
|
||||
# 10 kilobytes. When the file grows beyond this limit, older EVENTS will
|
||||
# be removed from the beginning of the file (first in first out). The
|
||||
# parameter EVENTSFILEMAX can be set to a different kilobyte value, or set
|
||||
# to zero to allow the EVENTSFILE to grow without limit.
|
||||
EVENTSFILEMAX 10
|
||||
|
||||
#
|
||||
# ========== Configuration statements used if sharing =============
|
||||
# a UPS with more than one machine
|
||||
|
||||
# NETTIME <int>
|
||||
# Interval (in seconds) at which the NIS client polls the server.
|
||||
# Used only when this apcupsd is a network client (UPSTYPE net).
|
||||
#NETTIME 60
|
||||
|
||||
#
|
||||
# Remaining items are for ShareUPS (APC expansion card) ONLY
|
||||
#
|
||||
|
||||
# UPSCLASS [ standalone | shareslave | sharemaster ]
|
||||
# Normally standalone unless you share an UPS using an APC ShareUPS
|
||||
# card.
|
||||
UPSCLASS standalone
|
||||
|
||||
# UPSMODE [ disable | share ]
|
||||
# Normally disable unless you share an UPS using an APC ShareUPS card.
|
||||
UPSMODE disable
|
||||
|
||||
#
|
||||
# ===== Configuration statements to control apcupsd system logging ========
|
||||
#
|
||||
|
||||
# Time interval in seconds between writing the STATUS file; 0 disables
|
||||
STATTIME 0
|
||||
|
||||
# Location of STATUS file (written to only if STATTIME is non-zero)
|
||||
STATFILE /var/log/apcupsd.status
|
||||
|
||||
# LOGSTATS [ on | off ] on enables, off disables
|
||||
# Note! This generates a lot of output, so if
|
||||
# you turn this on, be sure that the
|
||||
# file defined in syslog.conf for LOG_NOTICE is a named pipe.
|
||||
# You probably do not want this on.
|
||||
LOGSTATS off
|
||||
|
||||
# Time interval in seconds between writing the DATA records to
|
||||
# the log file. 0 disables.
|
||||
DATATIME 0
|
||||
|
||||
# FACILITY defines the logging facility (class) for logging to syslog.
|
||||
# If not specified, it defaults to "daemon". This is useful
|
||||
# if you want to separate the data logged by apcupsd from other
|
||||
# programs.
|
||||
#FACILITY DAEMON
|
||||
|
||||
#
|
||||
# ========== Configuration statements used in updating the UPS EPROM =========
|
||||
#
|
||||
|
||||
#
|
||||
# These statements are used only by apctest when choosing "Set EEPROM with conf
|
||||
# file values" from the EEPROM menu. THESE STATEMENTS HAVE NO EFFECT ON APCUPSD.
|
||||
#
|
||||
|
||||
# UPS name, max 8 characters
|
||||
#UPSNAME UPS_IDEN
|
||||
|
||||
# Battery date - 8 characters
|
||||
#BATTDATE mm/dd/yy
|
||||
|
||||
# Sensitivity to line voltage quality (H cause faster transfer to batteries)
|
||||
# SENSITIVITY H M L (default = H)
|
||||
#SENSITIVITY H
|
||||
|
||||
# UPS delay after power return (seconds)
|
||||
# WAKEUP 000 060 180 300 (default = 0)
|
||||
#WAKEUP 60
|
||||
|
||||
# UPS Grace period after request to power off (seconds)
|
||||
# SLEEP 020 180 300 600 (default = 20)
|
||||
#SLEEP 180
|
||||
|
||||
# Low line voltage causing transfer to batteries
|
||||
# The permitted values depend on your model as defined by last letter
|
||||
# of FIRMWARE or APCMODEL. Some representative values are:
|
||||
# D 106 103 100 097
|
||||
# M 177 172 168 182
|
||||
# A 092 090 088 086
|
||||
# I 208 204 200 196 (default = 0 => not valid)
|
||||
#LOTRANSFER 208
|
||||
|
||||
# High line voltage causing transfer to batteries
|
||||
# The permitted values depend on your model as defined by last letter
|
||||
# of FIRMWARE or APCMODEL. Some representative values are:
|
||||
# D 127 130 133 136
|
||||
# M 229 234 239 224
|
||||
# A 108 110 112 114
|
||||
# I 253 257 261 265 (default = 0 => not valid)
|
||||
#HITRANSFER 253
|
||||
|
||||
# Battery charge needed to restore power
|
||||
# RETURNCHARGE 00 15 50 90 (default = 15)
|
||||
#RETURNCHARGE 15
|
||||
|
||||
# Alarm delay
|
||||
# 0 = zero delay after pwr fail, T = power fail + 30 sec, L = low battery, N = never
|
||||
# BEEPSTATE 0 T L N (default = 0)
|
||||
#BEEPSTATE T
|
||||
|
||||
# Low battery warning delay in minutes
|
||||
# LOWBATT 02 05 07 10 (default = 02)
|
||||
#LOWBATT 2
|
||||
|
||||
# UPS Output voltage when running on batteries
|
||||
# The permitted values depend on your model as defined by last letter
|
||||
# of FIRMWARE or APCMODEL. Some representative values are:
|
||||
# D 115
|
||||
# M 208
|
||||
# A 100
|
||||
# I 230 240 220 225 (default = 0 => not valid)
|
||||
#OUTPUTVOLTS 230
|
||||
|
||||
# Self test interval in hours 336=2 weeks, 168=1 week, ON=at power on
|
||||
# SELFTEST 336 168 ON OFF (default = 336)
|
||||
#SELFTEST 336
|
12
net/apcupsd/files/apcupsd.init
Normal file
12
net/apcupsd/files/apcupsd.init
Normal file
@ -0,0 +1,12 @@
|
||||
#!/bin/sh /etc/rc.common
|
||||
# Copyright (C) 2006 OpenWrt.org
|
||||
START=50
|
||||
STOP=50
|
||||
|
||||
start() {
|
||||
/usr/sbin/apcupsd -f /etc/apcupsd/apcupsd.conf
|
||||
}
|
||||
|
||||
stop() {
|
||||
kill $(cat /var/run/apcupsd.pid)
|
||||
}
|
7
net/apcupsd/files/apcupsd_mail.conf
Normal file
7
net/apcupsd/files/apcupsd_mail.conf
Normal file
@ -0,0 +1,7 @@
|
||||
#!/bin/sh
|
||||
|
||||
MAILPROG="/usr/sbin/smtp"
|
||||
MAILHOST="mail:25"
|
||||
FROM="OpenWrt"
|
||||
TO="apcups@example.com"
|
||||
HOSTNAME="OpenWrt"
|
17
net/apcupsd/files/changeme
Normal file
17
net/apcupsd/files/changeme
Normal file
@ -0,0 +1,17 @@
|
||||
#!/bin/sh
|
||||
#
|
||||
# This shell script if placed in /etc/apcupsd
|
||||
# will be called by /etc/apcupsd/apccontrol when apcupsd
|
||||
# detects that the battery should be replaced.
|
||||
# We send an email message to root to notify him.
|
||||
#
|
||||
. /etc/apcupsd/apcupsd_mail.conf
|
||||
|
||||
MSG="$HOSTNAME UPS battery needs changing NOW."
|
||||
#
|
||||
(
|
||||
echo "$MSG"
|
||||
echo " "
|
||||
/usr/sbin/apcaccess status
|
||||
) | $MAILPROG -h $MAILHOST -F $FROM -s "$MSG" $TO
|
||||
exit 0
|
17
net/apcupsd/files/commfailure
Normal file
17
net/apcupsd/files/commfailure
Normal file
@ -0,0 +1,17 @@
|
||||
#!/bin/sh
|
||||
#
|
||||
# This shell script if placed in /etc/apcupsd
|
||||
# will be called by /etc/apcupsd/apccontrol when apcupsd
|
||||
# loses contact with the UPS (i.e. the serial connection is not responding).
|
||||
# We send an email message to root to notify him.
|
||||
#
|
||||
. /etc/apcupsd/apcupsd_mail.conf
|
||||
|
||||
MSG="$HOSTNAME Communications with UPS lost"
|
||||
#
|
||||
(
|
||||
echo "$MSG"
|
||||
echo " "
|
||||
/usr/sbin/apcaccess status
|
||||
) | $MAILPROG -h $MAILHOST -f $FROM -s "$MSG" $TO
|
||||
exit 0
|
17
net/apcupsd/files/commok
Normal file
17
net/apcupsd/files/commok
Normal file
@ -0,0 +1,17 @@
|
||||
#!/bin/sh
|
||||
#
|
||||
# This shell script if placed in /etc/apcupsd
|
||||
# will be called by /etc/apcupsd/apccontrol when apcupsd
|
||||
# restores contact with the UPS (i.e. the serial connection is restored).
|
||||
# We send an email message to root to notify him.
|
||||
#
|
||||
. /etc/apcupsd/apcupsd_mail.conf
|
||||
|
||||
MSG="$HOSTNAME Communications with UPS restored"
|
||||
#
|
||||
(
|
||||
echo "$MSG"
|
||||
echo " "
|
||||
/usr/sbin/apcaccess status
|
||||
) | $MAILPROG -h $MAILHOST -f $FROM -s "$MSG" $TO
|
||||
exit 0
|
17
net/apcupsd/files/offbattery
Normal file
17
net/apcupsd/files/offbattery
Normal file
@ -0,0 +1,17 @@
|
||||
#!/bin/sh
|
||||
#
|
||||
# This shell script if placed in /etc/apcupsd
|
||||
# will be called by /etc/apcupsd/apccontrol when the
|
||||
# UPS goes back on to the mains after a power failure.
|
||||
# We send an email message to root to notify him.
|
||||
#
|
||||
. /etc/apcupsd/apcupsd_mail.conf
|
||||
|
||||
MSG="$HOSTNAME Power has returned"
|
||||
#
|
||||
(
|
||||
echo "$MSG"
|
||||
echo " "
|
||||
/usr/sbin/apcaccess status
|
||||
) | $MAILPROG -h $MAILHOST -f $FROM -s "$MSG" $TO
|
||||
exit 0
|
17
net/apcupsd/files/onbattery
Normal file
17
net/apcupsd/files/onbattery
Normal file
@ -0,0 +1,17 @@
|
||||
#!/bin/sh
|
||||
#
|
||||
# This shell script if placed in /etc/apcupsd
|
||||
# will be called by /etc/apcupsd/apccontrol when the UPS
|
||||
# goes on batteries.
|
||||
# We send an email message to root to notify him.
|
||||
#
|
||||
. /etc/apcupsd/apcupsd_mail.conf
|
||||
|
||||
MSG="$HOSTNAME Power Failure !!!"
|
||||
#
|
||||
(
|
||||
echo "$MSG"
|
||||
echo " "
|
||||
/usr/sbin/apcaccess status
|
||||
) | $MAILPROG -h $MAILHOST -f $FROM -s "$MSG" $TO
|
||||
exit 0
|